Manufacturer
Urmas Rehvid OÜ
The container manufacturer provides a two-year warranty on the product and is responsible for ensuring the fire-resistance certificate of the materials used is in place.
Certified B2B solution
Fire resistance is proven, so an eight-metre safety distance is not required — the container can be installed right beside the building. Standard capacity 500 kWh.

Benefits
Four reasons why property owners choose the energy storage container solution.
REI60 construction, declaration of conformity and fire safety expert approval.
Fire resistance allows reducing the required eight-metre fire-safety separation.
Suits all battery and inverter brands. The internal climate is controlled. Cable lead-throughs run through the floor.
Painted steel frame, cast concrete floor, fire-resistant door and certified fire-safety dampers for ventilation.
Industrial companies may have a higher fire-resistance requirement, depending on the combustion load of production and the fire-safety separation requirement of up to 20 m (the final assessment is always given by a competent specialist for the specific site, as it also depends on neighbouring buildings and the condition of the plot).
Specs
A standard 500 kWh solution or fully to your project. All containers meet Estonian regulations and Nordic climate conditions.
500kWh
in a standard container
+20°C
outside air −30…+35 °C
Full solution
Manufacturer
The container manufacturer provides a two-year warranty on the product and is responsible for ensuring the fire-resistance certificate of the materials used is in place.
Installation partner
Official installation partner. Handles design, foundation, installation and grid connection.
Certificates
Every container passes quality control. From the manufacturer you receive documentation for approval and for applying for the installation permit.
The construction withstands fire for 60 minutes. During this time the fire-separating structure does not collapse and does not allow fire to spread.
The developed concept has been approved by a fire safety expert.
Designed for Nordic conditions — reliable down to −30 °C in winter and +35 °C in summer.
Every container is fully inspected: construction, tightness, climate unit and electrical system.
Standard dimensions allow ordinary transport and lifting by crane, without dismantling the container.
Gallery
Product exterior and interior views and the installation process (usage permit no. 2612996/04423).







Installed container — usage permit no. 2612996/04423
FAQ
Answers to technical and regulatory questions.
A REI60 construction withstands fire for 60 minutes. During this time the fire-separating structure does not collapse and does not allow fire to spread. The manufacturer is responsible for ensuring a fire-resistance certificate for the container's construction and the materials used. The developed concept has been approved by a fire safety expert.
Yes. The floor is cast concrete on an insulated and painted steel frame, dimensioned for the weight of the battery system installed in the container — up to 500 kWh in a standard container. The batteries are mounted on frames that distribute the load evenly rather than as a point load. For a custom solution the load-bearing capacity is recalculated to the project.
The container has an integrated air-source heat pump that keeps the internal temperature stable. The system works at outside temperatures from −30 to +35 °C, covering Estonian and Nordic conditions. Temperature matters: in the cold lithium batteries temporarily lose capacity, and in too much heat their lifespan shortens. The climate unit is not a convenience but part of protecting the investment.
The manufacturer is responsible for the container construction and for ensuring the fire-resistance certificate of the materials used is in place. The installation partner Aruna-Ehitus OÜ handles design, foundation, supply of storage and inverters, installation, grid connection and audit. For the client this means one partner and one responsibility — not separate procurements for the container, installation and connection.
A container in stock is available immediately. An order going into production is ready in 15–45 days, depending on the volume and whether it is a standard or custom solution. The installation time is agreed separately and depends on the readiness of the foundation and grid connection.
Yes. The container is movable by crane and built to withstand transport loads without being dismantled. This is exactly what sets the container solution apart from a storage room built on site.
The container is manufactured in the standard size of 3008 × 2008 × 2540 mm or fully to your project specification. In the choice of storage and inverters the solution is compatible with all brands, so it can be linked to an existing solar park or equipment fleet. In addition, further solutions can be ordered: security alarm, aerosol fire-suppression system, cameras, a humidity sensor, and so on. We put together the exact configuration during the initial consultation.
A standard container holds up to 500 kWh, which covers most industrial and commercial real-estate needs. The right capacity depends on the consumption profile, existing solar park and the goal — covering peak load, backup power or exploiting the exchange price difference. The initial assessment is free: send your consumption data and we will calculate the need.
Contact